Publication date: Available online 5 February 2017
Source:Annals of Diagnostic Pathology
Author(s): Clarissa A. Cassol, Juarez R. Braga, Samer Dabbo, K. Khalili, C. Avila-Casado
Percutaneous biopsy is a key diagnostic tool for both native and allograft kidney diseases. Adequacy criteria vary, but at a minimum, a biopsy should allow the pathologist to reach a diagnosis and provide prognostic information such as the degree of interstitial fibrosis and tubular atrophy (IF/TA) and percentage of glomerulosclerosis. Whereas most studies use glomerular counts as a surrogate for biopsy adequacy, the amount and preservation of tubulointerstitium is equally important, considering IF/TA is a major prognostic parameter for most medical renal diseases. Many studies have compared the diagnostic adequacy of different gauge needles; however few have investigated performance differences between same gauge needles. In this study, we retrospectively analyzed 235 renal biopsies performed at a single center in Canada over 2years to compare the utilization, safety, diagnostic and prognostic performance of two 18-gauge needles in native and allograft kidney biopsies. We found no significant difference in needle utilization between native and allograft kidneys, or between trainees and staff radiologists. The total tissue yielded area, glomerular counts, percentage of inadequate biopsies and number of passes were similar; however the number of cases in which IF/TA evaluation was deemed not possible was higher for biopsies using disposable instrument needles (4.3% vs. 0%; p=0.01). These also showed greater number of tissue fragments (median 4 for reusable vs 3 for disposable; p=0.04). We postulate that the increased tissue fragmentation might have impaired the pathologists ability to accurately assess interstitial fibrosis and tubular atrophy in biopsies obtained with the disposable instrument needles.
http://ift.tt/2kH0ltC
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,00306932607174,alsfakia@gmail.com,
Ετικέτες
Κυριακή 5 Φεβρουαρίου 2017
Effectiveness and safety of two 18-gauge needle types on native and allograft renal biopsies
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
-
Publication date: January–February 2018 Source: Materials Today, Volume 21, Issue 1 Author(s): David Bradley http://ift.tt/2BP...
-
Summary 外阴佩吉特病(VPD)是一种罕见的皮肤疾病,常见于绝经后的白人女性,它会引起外阴周围的皮肤瘙痒或灼烧。这种疾病有不同的类型,并且在过去,所有类型的 VPD 都与乳腺、肠道和泌尿系统的恶性肿瘤(如癌症)有关。这项来自荷兰的研究着眼于皮肤非侵入性 VPD, 其中在诊...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου