Dongping Shang, Jinbo Yue, Jianbin Li, Jinghao Duan, Yong Yin, Jinming Yu
Journal of Cancer Research and Therapeutics 2017 13(4):693-698
Purpose: To explore the impact of different width detector on the volume and geometric position of gross tumor volume (GTV) of the solitary pulmonary lesion (SPL), as well as the impact on scanning time and radiation dose during the simulation. Materials and Methods: Twenty-three patients with SPL underwent three-dimensional computed tomography (3DCT) simulation using different width detector, followed by four-dimensional computed tomography (4DCT) scans. GTV16 and GTV4 derived from different width detectors were compared with internal gross tumor volume (IGTV) generated from 4DCT on the volume and geometric position. Fourteen patients with lesions located in the upper lobe were defined as Group A and nine patients in the middle or lower lobe were defined as Group B. The scanning time and radiation dose during the simulation with the different width detector were compared as well. Results: The volumes of IGTV, GTV16, and GTV4 in Group A were 13.86 ± 14.42 cm3, 11.88 ± 11.93 cm3, and 11.64 ± 12.88 cm3, respectively, and the corresponding volumes in Group B were 12.84 ± 11.48 cm3, 6.90 ± 6.63 cm3, and 7.22 ± 7.15 cm3, respectively. No difference was found between GTV16 and GTV4 in Groups A and B (PA = 0.11, PB = 0.86). Either GTV16 or GTV4 was smaller than IGTV (P16 = 0.001, P4 = 0.000). The comparison of the centroidal positions in x, y, and z directions for GTV16, GTV4, and IGTV showed no significant difference both in Groups A and B (Group A: Px = 0.19, Py = 0.14, Pz = 0.47. Group B: Px = 0.09, Py = 0.90, Pz = 0.90). The scanning time was shorter and radiation dose patient received was lower using 16 × 1.5 mm detector combination than 4 × 1.5 mm detector (P = 0.000). Conclusions: Different width detector had no impact on the volume and geometric position of GTV of SPL during 3DCT simulation. Using wide detector would save time and decrease radiation dose compared with the narrow one. 3DCT simulation using either 16 × 1.5 mm detector or 4 × 1.5 mm detector could not cover all tumor motion information that 4DCT offered under free breathing conditions.
http://ift.tt/2xjVW5Z
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,00306932607174,alsfakia@gmail.com,
Ετικέτες
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
-
Publication date: January–February 2018 Source: Materials Today, Volume 21, Issue 1 Author(s): David Bradley http://ift.tt/2BP...
-
Summary 外阴佩吉特病(VPD)是一种罕见的皮肤疾病,常见于绝经后的白人女性,它会引起外阴周围的皮肤瘙痒或灼烧。这种疾病有不同的类型,并且在过去,所有类型的 VPD 都与乳腺、肠道和泌尿系统的恶性肿瘤(如癌症)有关。这项来自荷兰的研究着眼于皮肤非侵入性 VPD, 其中在诊...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου