Ετικέτες

Παρασκευή 9 Ιουνίου 2017

Fungal aerocontamination exposure risk for patients in 3 successive locations of a pediatric hematology unit department: Influence of air equipment and building structure on air quality

S01966553.gif

Publication date: Available online 8 June 2017
Source:American Journal of Infection Control
Author(s): Anne-Pauline Bellanger, Gabriel Reboux, Florent Demonmerot, Houssein Gbaguidi-Haore, Laurence Millon
BackgroundInvasive fungal infections (IFIs) play an important role in the mortality of immunocompromised patients. The pediatric hematology department (PHD) at Besançon University Hospital has relocated 3 times: (1) from a building without an air filtration system (B1), (2) to a renovated building with low air pressure (B2), and (3) to a new building with high air pressure and high-efficiency particulate air filters (B3). This study aimed to investigate how these relocations influenced the fungal exposure risk for the PHD's patients.MethodsAir samples were taken monthly in patient rooms and weekly in corridors. The detection of opportunistic fungi species was used to assess IFI risk. Data were analyzed using univariate and multivariate random-effects negative binomial regression.ResultsA total of 1,074 samples from 29 rooms over a 10-year period showed that renovation of an old building with a basic ventilation system did not lead to a significant improvement of air quality (P = .004, multivariate analysis). Among factors linked to higher risk of patient rooms mold contamination was fungal contamination of the corridors (P < .001).ConclusionsThis study demonstrates that corridors can be used as reliable sentinel to prevent fungal contamination in patient rooms. Only relocation in building B3, equipped with laminar air flow, achieved adequate air quality.



http://ift.tt/2sbFqDr

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου

Αναζήτηση αυτού του ιστολογίου