Publication date: 1 March 2018
Source:Talanta, Volume 179
Author(s): Yanyan Qu, Liangliang Sun, Guijie Zhu, Zhenbin Zhang, Elizabeth H. Peuchen, Norman J. Dovichi
Glycoproteomic analysis requires efficient separation and sensitive detection to enable the comprehensive characterization of glycan heterogeneity. Here, we report the use of capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) with an electrokinetically-pumped nanospray interface for the study of protein glycosylation microheterogeneity. A fast separation was developed that resolved intact glycopeptides generated from standard proteins within ~9min. Differentially terminal-galactosylated and sialylated species with the same glycosylation sites were well resolved. The concentration detection limits for CZE were three times higher than for nanoLC methods; however, a 200-fold smaller injection volume was used in CZE, which reflects the use of an extremely efficient electrospray interface in our CZE-ESI-MS setup. The resulting glycopeptide mass detection limit was two orders of magnitude superior to a nanoLC method. We also observed a 1.5% and 7% average relative standard deviation in peak migration time and glycopeptide relative abundance, and a four order of magnitude linear dynamic range in signal intensity. With CZE-ESI-MS, 40 haptoglobin glycopeptides were identified from roughly 40 fmol of digest.