Source:Magnetic Resonance Imaging, Volume 51
Author(s): Peter Latta, Zenon Starčuk, Marco L.H. Gruwel, Barbora Lattova, Petra Lattova, Pavel Štourač, Boguslaw Tomanek
PurposeTo evaluate the impact of MR gradient system imperfections and limitations for the quantitative mapping of short T2* signals performed by ultrashort echo time (UTE) acquisition approach.Materials and methodsThe measurement of short T2* signals from a phantom and a healthy volunteer study (8 subjects of average age 28 ± 4 years) were performed on a 3T scanner. The characteristics of the gradient system were obtained using calibration method performed directly on the measured subject or phantom. This information was used to calculate the actual sampling trajectory with the help of a parametric eddy current model. The actual sample positions were used to reconstruct corrected images and compared with uncorrected data.ResultsComparison of both approaches, i.e., without and with correction of k-space sampling trajectories revealed substantial improvement when correction was applied. The phantom experiments demonstrate substantial in-plane signal intensity variations for uncorrected sampling trajectories. In the case of the volunteer study, this led to significant differences in relative proton density (RPD) estimation between the uncorrected and corrected data (P = 0.0117 by Wilcoxon matched-pairs test) and provides for about ~15% higher values for short T2* components of white matter (WM) in the case of uncorrected images.ConclusionThe imperfection of the applied gradients could induce errors in k-space data sampling which further propagates into the fidelity of the UTE images and jeopardizes precision of quantification. However, the study proved that measurement of gradient errors together with correction of sample positions can contribute to increased accuracy and unbiased characterization of short T2* signals.
https://ift.tt/2IGMexp
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,00306932607174,alsfakia@gmail.com,
Ετικέτες
Τετάρτη 23 Μαΐου 2018
Influence of k-space trajectory corrections on proton density mapping with ultrashort echo time imaging: Application for imaging of short T2 components in white matter
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
-
Ειδοποίηση Μελετητή:[ ωτα ] [HTML] Gender, identity and material: Film screening C Brand - 2017 ftypM4V *M4V M4A mp42isom*a┌moovlmvhd...
-
Summary 外阴佩吉特病(VPD)是一种罕见的皮肤疾病,常见于绝经后的白人女性,它会引起外阴周围的皮肤瘙痒或灼烧。这种疾病有不同的类型,并且在过去,所有类型的 VPD 都与乳腺、肠道和泌尿系统的恶性肿瘤(如癌症)有关。这项来自荷兰的研究着眼于皮肤非侵入性 VPD, 其中在诊...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου