Ετικέτες

Πέμπτη 6 Σεπτεμβρίου 2018

Heart-sparing volumetric modulated arc therapy for whole lung irradiation

Abstract

Purpose

Whole lung irradiation (WLI) is indicated for subgroups of patients with lung metastases from Wilms' tumor (nephroblastoma). WLI has traditionally been performed with an anterior/posterior field arrangement with poor potential for heart sparing; thus, new techniques are desirable to achieve a lower dose to the heart.

Materials and methods

We utilized volumetric modulated arc therapy (VMAT) for WLI with 18 Gy in a patient with metastatic nephroblastoma. The planning results were compared against a three-dimensional (3D) conformal plan.

Results

VMAT resulted in adequate target volume coverage with the prescribed dose. Mean heart dose was 10.2 Gy. The dose to organs at risk (OAR) was generally more favorable with VMAT when compared with a 3D-conformal radiotherapy plan.

Discussion

WLI with VMAT provides superior sparing of OARs and especially a considerably lower dose to the heart.