BACKGROUND Flow-controlled ventilation (FCV) is a new mechanical ventilation mode that maintains constant flow during inspiration and expiration with standard tidal volumes via cuffed narrow-bore endotracheal tubes. Originating in manually operated 'expiratory ventilation assistance', FCV extends this technique by automatic control of airway flow, monitoring of intratracheal pressure and control of peak inspiratory pressure and end-expiratory pressure. FCV has not yet been described in a clinical study. OBJECTIVE The aim of this study was to provide an initial assessment of FCV in mechanically ventilated patients undergoing ear, nose and throat surgery and evaluate its potential for future use. DESIGN An observational study. SETTING Two German academic medical centres from 24 November 2017 to 09 January 2018. PATIENTS Consecutive patients (≥ 18 years) scheduled for elective ear, nose and throat surgery. Exclusion criteria were planned laser surgery, intended fibreoptic awake intubation, emergency procedures, increased risk of aspiration, American Society of Anesthesiologists (ASA) physical status more than III and chronic obstructive pulmonary disease classified as GOLD stage more than II. INTERVENTION Peri-operative use of FCV provided by a new type of ventilator (Evone) via a narrow-bore endotracheal tube (Tritube). MAIN OUTCOME MEASURES Minute volume, respiratory rate, intratidal tracheal pressure amplitude (Δp) and end-tidal CO2 (PetCO2) were recorded every 5 min. All adverse events were noted. Data are presented as median [IQR]. RESULTS Sixteen patients provided 15 evaluable data sets. A minute volume of 5.0 [4.4 to 6.4] l min−1 and a respiratory rate of 9 [8 to 11] min−1 generated a PetCO2 of 4.9 [4.8 to 5.0] kPa. Δp was 10 [9 to 12] cmH2O. Five adverse events were recorded: a tube obstruction due to airway secretions and four tube dislocations (two attributed to coughing, two not study-related). CONCLUSION FCV achieves adequate PetCO2 levels with minute volume and Δp in the normal range. Tritube's high flow resistance may increase the likelihood of tube dislocations if the patient coughs. Although further evaluation is necessary, FCV provides a new option for short-term mechanical ventilation. The successful operation of FCV with narrow-bore tubes contributes to the armamentarium for airway management. TRIAL REGISTRATION DRKS00013312 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://bit.ly/OBJ4xP Correspondence to Dr. Johannes Schmidt, Department of Anaesthesiology and Critical Care, Medical Centre – University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany Tel: +49 761 270 26390; e-mail: johannes.schmidt@uniklinik-freiburg.de Supplemental digital content is available for this article. Direct URL citations appear in the printed text and are provided in the HTML and PDF versions of this article on the journal's Website (http://bit.ly/2ylyqmW). © 2019 European Society of Anaesthesiology
http://bit.ly/2SsAarR
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,00306932607174,alsfakia@gmail.com,
Ετικέτες
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
-
Summary Insulinomas are rare neuroendocrine tumours that classically present with fasting hypoglycaemia. This case report discusses an un...
-
The online platform for Taylor & Francis Online content New for Canadian Journal of Remote Sen...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου