Thoracic Imaging

Editors' Recognition for Reviewing in 2020
No abstract available

Establishing Satellite Lung Cancer Screening Sites With Telehealth to Address Disparities Between High-risk Smokers and American College of Radiology–approved Centers of Designation
imageNo abstract available

The Regimen of Computed Tomography Screening for Lung Cancer: Lessons Learned Over 25 Years From the International Early Lung Cancer Action Program
imageWe learned many unanticipated and valuable lessons since we started planning our study of low-dose computed tomography (CT) screening for lung cancer in 1991. The publication of the baseline results of the Early Lung Cancer Action Project (ELCAP) in Lancet 1999 showed that CT screening could identify a high proportion of early, curable lung cancers. This stimulated large national screening studies to be quickly started. The ELCAP design, which provided evidence about screening in the context of a clinical program, was able to rapidly expand to a 12-institution study in New York State (NY-ELCAP) and to many international institutions (International-ELCAP), ultimately working with 82 institutions, all using the common I-ELCAP protocol. This expansion was possible because the investigators had developed the ELCAP Management System for screening, capturing data and CT images, and providing for quality assurance. This advanced registry and its rapid accumulation of data and images allowed continual assessment and updating of the regimen of screening as advances in knowledge and new technology emerged. For example, in the initial ELCAP study, introduction of helical CT scanners had allowed imaging of the entire lungs in a single breath, but the images were obtained in 10 mm increments resulting in about 30 images per person. Today, images are obtained in submillimeter slice thickness, resulting in around 700 images per person, which are viewed on high-resolution monitors. The regimen provides the imaging acquisition parameters, imaging interpretation, definition of positive result, and the recommendations for further workup, which now include identification of emphysema and coronary artery calcifications. Continual updating is critical to maximize the benefit of screening and to minimize potential harms. Insights were gained about the natural history of lung cancers, identification and management of nodule subtypes, increased understanding of nodule imaging and pathologic features, and measurement variability inherent in CT scanners. The registry also provides the foundation for assessment of new statistical techniques, including artificial intelligence, and integration of effective genomic and blood-based biomarkers, as they are developed.

Private Tour Guide to Pediatric Coronavirus Disease of 2019 and Multisystem Inflammatory Syndrome in Children in 10 Minutes: What Thoracic Radiologists Need to Know
imageFiltering through the plethora of radiologic studies generated in response to the coronavirus disease of 2019 (COVID-19) pandemic can be time consuming and impractical for practicing thoracic radiologists with busy clinical schedules. To further complicate matters, several of the imaging findings in the pediatric patients differ from the adult population. This article is designed to highlight clinically useful information regarding the imaging manifestations of pediatric COVID-19 pneumonia, including findings more unique to pediatric patients, and multisystem inflammatory syndrome in children.

Performance of Chest Computed Tomography in Differentiating Coronavirus Disease 2019 From Other Viral Infections Using a Standardized Classification
imageBackground: An expert consensus recently proposed a standardized coronavirus disease 2019 (COVID-19) reporting language for computed tomography (CT) findings of COVID-19 pneumonia. Purpose: The purpose of the study was to evaluate the performance of CT in differentiating COVID-19 from other viral infections using a standardized reporting classification. Methods: A total of 175 consecutive patients were retrospectively identified from a single tertiary-care medical center from March 15 to March 24, 2020, including 87 with positive reverse transcription-polymerase chain reaction (RT-PCR) test for COVID-19 and 88 with negative COVID-19 RT-PCR test, but positive respiratory pathogen panel. Two thoracic radiologists, who were blinded to RT-PCR and respiratory pathogen panel results, reviewed chest CT images independently and classified the imaging findings under 4 categories: "typical" appearance, "indeterminate," "atypical," and "negative" for pneumonia. The final classification was based on consensus between the readers. Results: Patients with COVID-19 were older than patients with other viral infections (P=0.038). The inter-rater agreement of CT categories between the readers ranged from good to excellent, κ=0.80 (0.73 to 0.87). Final CT categories were statistically different among COVID-19 and non-COVID-19 groups (P<0.001). CT "typical" appearance was more prevalent in the COVID-19 group (64/87, 73.6%) than in the non-COVID-19 group (2/88, 2.3%). When considering CT "typical" appearance as a positive test, a sensitivity of 73.6% (95% confidence interval [CI]: 63%-82.4%), specificity of 97.7% (95% CI: 92%-99.7%), positive predictive value of 97% (95% CI: 89.5%-99.6%), and negative predictive value of 78.9% (95% CI: 70%-86.1%) were observed. Conclusion: The standardized chest CT classification demonstrated high specificity and positive predictive value in differentiating COVID-19 from other viral infections when presenting a "typical" appearance in a high pretest probability environment. Good to excellent inter-rater agreement was found regarding the CT standardized categories between the readers.

A Dose Simulation X-Ray Software: An Innovating Tool to Reduce Chest Radiograph Exposure in Children
imagePurpose: Chest radiography is one of the most frequent x-ray examinations performed on children. Reducing the delivered dose is always a major task. The objective of our study was to determine the minimum dose to be delivered while maintaining the image quality of chest radiographs, using dose reduction simulation software. Materials and Methods: We included 60 children who had had a chest radiography in 5 groups established according to the diagnostic reference levels equitably represented by weight ranges. The software simulated for each radiograph 6 additional simulated photonic noise images corresponding to 100%, 80%, 64%, 50%, 40%, and 32% of the initial dose. The 360 radiographs were blindly scored by 2 radiologists, according to the 7 European quality criteria and a subjective criterion of interpretability, using a semiquantitative visual Lickert scale. Results: There was no significant difference in scoring between the reference radiograph (100%) and simulated radiographs at 80% of the dose in children between 5 and 20 kg, 50% of the dose in children between 20 and 30 kg, and between simulated radiographs at 40% of the dose in children over 30 kg. Interobserver reproducibility was moderate to excellent. Conclusion: Chest radiography dose might be reduced by 20% in children between 5 and 20 kg, 50% in children between 20 and 30 kg, and 60% in children over 30 kg, without any difference in the image quality appreciation. Software that produced simulated x-ray with decreasing delivered dose is an innovating tool for an optimization process.

Three-dimensional Ultrashort Echotime Magnetic Resonance Imaging for Combined Morphologic and Ventilation Imaging in Pediatric Patients With Pulmonary Disease
imagePurpose: Ultrashort echotime (UTE) sequences aim to improve the signal yield in pulmonary magnetic resonance imaging (MRI). We demonstrate the initial results of spiral 3-dimensional (3D) UTE-MRI for combined morphologic and functional imaging in pediatric patients. Methods: Seven pediatric patients with pulmonary abnormalities were included in this observational, prospective, single-center study, with the patients having the following conditions: cystic fibrosis (CF) with middle lobe atelectasis, CF with allergic bronchopulmonary aspergillosis, primary ciliary dyskinesia, air trapping, congenital lobar overinflation, congenital pulmonary airway malformation, and pulmonary hamartoma. Patients were scanned during breath-hold in 5 breathing states on a 3-Tesla system using a prototypical 3D stack-of-spirals UTE sequence. Ventilation maps and signal intensity maps were calculated. Morphologic images, ventilation-weighted maps, and signal intensity maps of the lungs of each patient were assessed intraindividually and compared with reference examinations. Results: With a scan time of ∼15 seconds per breathing state, 3D UTE-MRI allowed for sufficient imaging of both "plus" pathologies (atelectasis, inflammatory consolidation, and pulmonary hamartoma) and "minus" pathologies (congenital lobar overinflation, congenital pulmonary airway malformation, and air trapping). Color-coded maps of normalized signal intensity and ventilation increased diagnostic confidence, particularly with regard to "minus" pathologies. UTE-MRI detected new atelectasis in an asymptomatic CF patient, allowing for rapid and successful therapy initiation, and it was able to reproduce atelectasis and hamartoma known from multidetector computed tomography and to monitor a patient with allergic bronchopulmonary aspergillosis. Conclusion: 3D UTE-MRI using a stack-of-spirals trajectory enables combined morphologic and functional imaging of the lungs within ~115 second acquisition time and might be suitable for monitoring a wide spectrum of pulmonary diseases.

Radiation Dose Reduction Using a Novel Fluoroscopy System in Patients Undergoing Diagnostic Invasive Coronary Angiography
imageBackground: Invasive coronary angiography (ICA) still causes a significant amount of radiation exposure for patients and operators. In February 2017, the Azurion system was introduced, a new-generation fluoroscopy image acquisition and processing system. Radiation exposure in patients undergoing ICA was assessed comparing the novel Azurion 7 F12 angiography system to its predecessor Allura Xper in a randomized manner. Methods: Radiation exposure was prospectively analyzed in 238 patients undergoing diagnostic ICA. Patients were randomly assigned to the novel Azurion system (119 patients) or its predecessor Allura Xper system (119 patients). In each patient, 8 predefined standard projections (5 left coronary artery, 3 right coronary artery) were performed. Image quality was quantified by grading of the images on the basis of a 5-point grading system. Results: Radiation dose area product was significantly lower in the Azurion group 109 (interquartile range [IQR 75-176] cGy cm2) compared with the Allura Xper group 208 [IQR 134-301] cGy cm2 (P<0.001). Body mass index (26.6 [IQR 23.9-29.7] kg/m2 vs. 26.2 [IQR 24.2-29.4] kg/m2; P=0.607), body surface area (1.96 [IQR 1.81-2.11] m2 vs. 1.90 [IQR 1.77-20.4] m2; P=0.092), and procedure duration (1.5 [IQR 1.2-2.3] min vs. 1.6 [IQR 1.2-2.5] min; P=0.419) were similar in both groups. Images from the Azurion system were at least of equal quality compared with Allura Xper (image quality grade 4.82±0.45 vs. 4.75±0.52, P=0.43). Conclusion: Use of the novel Azurion 7 F12 angiography system resulted in a significant reduction of dose area product in patients undergoing diagnostic ICA by 56%.

Prevalence of Burnout Among Cardiothoracic Radiologists
imagePurpose: Burnout is a psychological syndrome in response to chronic occupational stressors. The prevalence of burnout among medical professionals has been increasing, and recent studies have shown that radiologists are among those affected. We investigated the prevalence of burnout and assessed associated factors among cardiothoracic radiologists. Materials and Methods: Society of Thoracic Radiology members were invited to complete an anonymous cross-sectional survey that included an adapted Maslach Burnout Inventory and questions about demographics, work place characteristics, and stressors. Results: The survey response rate was 33.1% (290/874). Per-item response rate ranged from 94% to 100% with a median of 99%. The prevalence of emotional exhaustion was 66.8% (186/283), depersonalization was 79% (223/283), and low personal accomplishment was 23% (65/280). There were no statistically significant differences between academic and private practice. There was a trend toward worse burnout in women, but this was not statistically significant. Being in early career (0 to 10 y since fellowship) was associated with low personal accomplishment [odds ratio (OR): 2.07, 95% confidence interval (CI): 1.08-3.99]. Those working fewer than 51 hours per week were significantly less likely to report emotional exhaustion (OR: 0.55, 95% CI: 0.33-0.90). The odds of emotional exhaustion for those producing fewer than 7500 work relative value units per year were approximately half of those exceeding that number (OR: 0.46, 95% CI: 0.22-0.95). Conclusions: The prevalence of burnout among cardiothoracic radiologists is comparable to that reported for radiologists in other subspecialties such as musculoskeletal and interventional radiology. High work relative value unit productivity and longer work hours are associated with higher prevalence of burnout.

COVID-19 and its Mimics: What the Radiologist Needs to Know
imageSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is responsible for the current outbreak of Coronavirus disease 2019 (COVID-19). Although imaging should not be used for first-line screening or diagnosis, radiologists need to be aware of its imaging features, and those of common conditions that may mimic COVID-19 pneumonia. In this Pictorial Essay, we review frequently encountered conditions with imaging features that overlap with those that are typical of COVID-19 (including other viral pneumonias, chronic eosinophilic pneumonia, and organizing pneumonia), and those with features that are indeterminate for COVID-19 (including hypersensitivity pneumonitis, pneumocystis pneumonia, diffuse alveolar hemorrhage, pulmonary edema, and pulmonary alveolar proteinosis).


#