PurposeThe quality of a low–dose rate prostate brachytherapy implant depends on the accurate placement of sources in their planned locations. This study investigates intraoperative factors that potentially contribute to stranded source placement inaccuracy in prostate brachytherapy.Methods and MaterialsIntraoperative video images of the brachytherapist's hand motions and needle insertions during the implant procedure were acquired for analysis. Using video analysis software, maximum and average needle insertion velocities were determined. The number of needle insertion attempts and the use of the brachytherapist's other hand to manipulate the needle direction were also recorded. Sources misplacements were analyzed using an ultrasound-based method described elsewhere.ResultsFifteen patients agreed to undergo this study; 1619 125I seeds were inserted using 357 needles; 1197 seeds were confidently identified using ultrasound images and included in the analysis. The mean overall misplacement was 0.49 cm (0–2 cm, 95% CI = 0.47–0.51); 614 seeds were delivered with a single pass and 583 seeds with >1 passes (range 2–6). The mean maximum needle velocity was 12.34 cm s−1 (range 4–28 cm s−1) and mean average velocity was 4.76 cm s−1 (range 0.4–17.4 cm s−1); 747 seeds were delivered with manipulation of the needle. The generalized linear model test was used to analyze factors contributing to seed misplacement, and it was found that a maximum speed <12 cm s−1 was associated with a decrease in seed misplacement by 0.049 cm vs. a maximum speed >12 cm s−1, p = 0.0121). Other evaluated factors were found to have no statistically significant correlation with seed misplacement: average speed (p = 0.4947), manual manipulation of needle (p = 0.9264), and number of needle passes (p = 0.8907).ConclusionsThis study identified that needles inserted with lower maximum velocity were associated with less seed misplacement. Manual manipulation of the needle, number of passes, and average speed did not show statistically significant correlation with seed misplacement.
http://ift.tt/2kvIJxU
Medicine by Alexandros G. Sfakianakis,Anapafseos 5 Agios Nikolaos 72100 Crete Greece,00302841026182,00306932607174,alsfakia@gmail.com,
Ετικέτες
Παρασκευή 10 Φεβρουαρίου 2017
Intraoperative factors associated with stranded source placement accuracy in low–dose rate prostate brachytherapy
Εγγραφή σε:
Σχόλια ανάρτησης (Atom)
-
Ειδοποίηση Μελετητή:[ ωτα ] [HTML] Gender, identity and material: Film screening C Brand - 2017 ftypM4V *M4V M4A mp42isom*a┌moovlmvhd...
-
Summary 外阴佩吉特病(VPD)是一种罕见的皮肤疾病,常见于绝经后的白人女性,它会引起外阴周围的皮肤瘙痒或灼烧。这种疾病有不同的类型,并且在过去,所有类型的 VPD 都与乳腺、肠道和泌尿系统的恶性肿瘤(如癌症)有关。这项来自荷兰的研究着眼于皮肤非侵入性 VPD, 其中在诊...
Δεν υπάρχουν σχόλια:
Δημοσίευση σχολίου