Comparison of force loss due to friction of different wire sizes and materials in conventional and new self-ligating orthodontic brackets during simulated canine retraction

Abstract

Aims

The aim of this study was to compare force loss due to friction (Fr) during simulated canine retraction using different archwire dimensions and materials between conventional and new self-ligating brackets.

Methods

The tested brackets were (1) conventional brackets (Victory series, GAC twin and FLI twin), (2) self-ligating brackets (Damon-Q, FLI-SL, new/improved FLI-SL (I FLI-SL), SPEED, GAC innovation (R) and Ortho Classic) and (3) a low-friction bracket (Synergy). All brackets had a 0.022″ slot size. The tested archwires were stainless steel (0.018″; 0.016″x0.022″; 0.017″x0.025″; 0.018″x0.025″ and 0.019″x0.025″); nickel titanium (NiTi; 0.016″x0.022″; 0.017″x0.025″; 0.018″x0.025″ and 0.019″x0.025″) and titanium molybdenum alloy (TMA; 0.016″x0.022″; 0.017″x0.025″; 0.018″x0.025″ and 0.019″x0.025″). Canine retraction was experimentally simulated in a biomechanical set-up using a NiTi coil spring that delivered a force of 1 N. The simulated retraction path was up to 4 mm. Force loss due to friction was compared between groups using the Welch t‑test.

Results

Force loss due to friction increased with increasing archwire size. Also, TMA showed the highest and stainless steel the lowest force loss due to friction. FLI-SL brackets showed the lowest Fr (31%) and Ortho Classic showed the highest (67%).

Conclusions

Increasing wire size generally showed increasing force loss due to friction. FLI-SL brackets showed the lowest, while Ortho Classic showed the highest friction.